U R P R O D U C T S
UR Products

Addressable Fire Alarm Control Panel (8 Loops)

Home Products
Addressable Fire Alarm Control Panel (8 Loops)

Addressable Fire Alarm Control Panel (8 Loops)

Touchscreen addressable panel — up to 8 loops of 250 devices, wireless groups and a GSM option.

This machine can be connected to 8 loops. Each loop can be connected to 250 devices, such as smoke detectors, temperature detectors, input/output modules, each loop can be connected to 10 groups of wireless loops, a group of wireless loops can be connected to 20 devices, such as smoke detector, temperature detector, input and output module, etc. Features • 7-inch color LCD display, touch screen operation • All addressable devices use a two-wire system • A wired loop can  connect  250  wired  addressable  devices • One set of wireless loops can connect to 20 devices • Max 8 loop cards can be installed • Up to 999 records of history can be saved (save when power off) • Multiple access levels can be set • It has a rechargeable backup battery • Can simply judge the running status of the machine based on the  LED lights • Automatic search device • Each of the 8 hosts CAN be controlled remotely • USB software upper computer to check and set the device status and fire history records • It can bind 10 mobile phone numbers to receive host alarm information. (The GSM module must be added) Technical specifications Technical Specification Rated input voltage: 85-260VAC 50Hz/60Hz Standby battery: Two 12V/7Ah lead-acid batteries in series Working environment: Relative humidity (<95%) at -10 ~45 ℃, no condensation) Fuse: AC power input fuse: 3.15A/250V 5*20mm, Glass tube fuse slowly blow Battery output fuse: 10A/250V 5*20mm, Glass tube fuse, slowly blow Auxiliary power supply: Resettable 24VDC 200mA (Max) F.A output: Normal output -12VDC Fire alarm output 24VDC/200mA (Max) Fault output: Normal output is 24VDC/200mA (Max), and the fault is output -12VDC S.C output: Normal state output - 12VDC Active state output -24VDC/200mA (Max) Maximum Load Current per Loop: 24VDC 1A(Max) Terminal blocks rating: All terminals rated for 12 to18 AWG (0.75 to 2.5 mm2) Screened or unscreened twisted-pair, Transmission distance ≤1000m

Product Features & Details

This product is designed to deliver a practical and reliable security solution with stable performance for residential and commercial use.

It can be used within modern surveillance and protection setups with easier installation, operation, and stronger site management.

Key Highlights

  • Reliable quality
  • Competitive pricing
  • Suitable for facilities
  • Stable performance
  • Easy integration
  • Ready to deploy

Additional Description

This machine can be connected to 8 loops. Each loop can be connected to 250 devices, such as smoke detectors, temperature detectors, input/output modules, each loop can be connected to 10 groups of wireless loops, a group of wireless loops can be connected to 20 devices, such as smoke detector, temperature detector, input and output module, etc.

Features
• 7-inch color LCD display, touch screen operation
• All addressable devices use a two-wire system
• A wired loop can  connect  250  wired  addressable  devices
• One set of wireless loops can connect to 20 devices
• Max 8 loop cards can be installed
• Up to 999 records of history can be saved (save when power off)
• Multiple access levels can be set
• It has a rechargeable backup battery
• Can simply judge the running status of the machine based on the  LED lights
• Automatic search device
• Each of the 8 hosts CAN be controlled remotely
• USB software upper computer to check and set the device status and fire history records
• It can bind 10 mobile phone numbers to receive host alarm information. (The GSM module must be added)

Technical specifications
Technical Specification
Rated input voltage: 85-260VAC 50Hz/60Hz
Standby battery: Two 12V/7Ah lead-acid batteries in series
Working environment: Relative humidity (<95%) at -10 ~45 ℃, no condensation)
Fuse: AC power input fuse: 3.15A/250V 5*20mm, Glass tube fuse slowly blow Battery output fuse: 10A/250V 5*20mm, Glass tube fuse, slowly blow
Auxiliary power supply: Resettable 24VDC 200mA (Max)
F.A output: Normal output -12VDC Fire alarm output 24VDC/200mA (Max)
Fault output: Normal output is 24VDC/200mA (Max), and the fault is output -12VDC
S.C output: Normal state output - 12VDC Active state output -24VDC/200mA (Max)
Maximum Load Current per Loop: 24VDC 1A(Max)
Terminal blocks rating: All terminals rated for 12 to18 AWG (0.75 to 2.5 mm2) Screened or unscreened twisted-pair, Transmission distance ≤1000m
Addressable Fire Alarm Control Panel (8 Loops)
Addressable Fire Alarm Control Panel (8 Loops)

View More Products

IP Cameras
IP Cameras

Fixed bullet, dome and turret IP cameras produced on our own lines in a full range of resolutions.

Learn More
Thermal Cameras
Thermal Cameras

Cooled and uncooled thermal imaging, long-range PTZ and multi-sensor systems for perimeter and indus...

Learn More
NVR & XVR Recorders
NVR & XVR Recorders

Network and hybrid video recorders from 4 to 64 channels, with PoE switching built in.

Learn More